Power disturbance analysis for electrical engineers

A panel instrument records disturbances, frequency changes and motor inrush alongside routine measurements. Engineers inspect stored events, compare harmonics and export data for detailed supply assessment.

Power disturbance analysis for electrical engineers, image 1 of 3Power disturbance analysis for electrical engineers, image 2 of 3Power disturbance analysis for electrical engineers, image 3 of 3
Algodue
Connectivity
Wi-Fi, Ethernet, RS-485
Deployment
Edge/Local
Services
Software Platform, Support & Maintenance

About Power disturbance analysis for electrical engineers

Electrical supply assessment from Algodue records voltage and current behaviour to help engineers investigate disturbances. The PQM4000 panel analyzer captures voltage events, frequency variation and inrush current alongside routine three-phase measurements. Its records also include flicker, imbalance, harmonics and interharmonics for later review.

The instrument has separate versions for standard current transformers or current clamps. Transformer inputs use 1 A or 5 A outputs, while additional measurement channels support neutral potential and earth-leakage current checks. Ethernet, RS485 and WiFi provide network access; the embedded web server presents live values and graphics. Modbus RTU and Modbus TCP support connection with monitoring systems, and a USB host port transfers recorded data.

Engineers export PQDIF or CSV files for analysis and use the local touchscreen or web interface to examine events. PQM Tool is the monitoring application, while PQM Analyzer evaluates recorded supply data. The device records events, minimum, average and maximum logs and energy counters together. An internal rechargeable backup battery supports short interruptions, and GPS timing helps align recorded events when comparing the instrument's data with other electrical measurements.

How it works

Sense
Capture voltage, current, harmonics and disturbance events
Connect
Access instrument data over Ethernet, RS485 or WiFi
Analyze
Inspect waveforms and compare recorded electrical events
Act
Export event files and plan corrective supply investigations

Does it fit your project?

Best suited to

  • Electrical supply investigation teams
  • Industrial switchboard disturbance review
  • Motor inrush current studies

You need

  • PQM4000 and matching transformers or clamps
  • Ethernet, RS485 or WiFi connection
  • PQM Tool or PQM Analyzer
  • Auxiliary AC or DC supply

Limitations

  • Transformers or current clamps purchased separately
  • Requires matching transformer or clamp model
  • Maximum 1000 V phase-to-phase direct input

Cost estimate

Set your scope, see what a Power disturbance analysis for electrical engineers deployment costs, then ask Algodue to confirm a price and lead time. The estimate is free and needs no contact details.

1Your project

United States
Any
Any
Any
None
No

2Your estimate

$1,400 – $4,700
$300 – $1,000
$500 – $1,600$600 – $2,100$300 – $1,000
Hardware$500 – $1,600

Sensors, gateways and spare units

Installation and setup$600 – $2,100

Site survey, mounting, commissioning and configuration

Software and services$300 – $1,000

Platform subscription, connectivity, data and support

IoT Apps estimate in USD for 1 site and 10 assets in the United States, from comparable deployments, reviewed September 2026. Not a quote from Algodue. Excludes taxes, shipping, civil works and custom integration. How IoT Apps estimates costs

My budget, first year$2,500 – $3,600
Budget status

The band starts on the medium range of the estimate. Pick the one that matches your plans, or Not sure; Algodue sees your budget as indicative unless you mark it approved.

3Ask Algodue to confirm price and lead time

Your details

Name, company and work email are required. Phone is optional.

Hide project details

Company size, project stage and decision timing tell Algodue how firm the project is and which offer fits: a budgeted project with a decision this quarter gets a firm price and lead time, an early enquiry gets guidance first.

Choose
Choose
Choose
Algodue receives
Scope1 site, 10 assets, United States, any connectivityBudget$2,500 – $3,600 first year, indicativeYour noteEverything you write belowYour contactName, company and email, when you choose the vendor
Algodue confirms
Price for this scope
Lead time
What is included and what the installation needs
Anything Algodue should know
Ask Algodue to confirmAdd other matching solutions

IoT Apps sends the request to Algodue and keeps a copy. Vendors usually answer within two working days; IoT Apps follows up if you have no reply after three.

Similar solutions

See all solutions
Machine vibration and temperature tracking for plants
Machine vibration and temperature tracking for plantsby Asystom

Multisensor beacons use LoRaWAN gateways to send ultrasound readings and learned anomaly records.

SF6 loss alerts for electrical maintenance teams
SF6 loss alerts for electrical maintenance teamsby bemondis

LoRaWAN density sensors feed a cloud view so staff can check critical insulation gas changes.

Plant machinery diagnostics for industrial reliability teams
Plant machinery diagnostics for industrial reliability teamsby Bently Nevada

Machine systems feed operating data to connected software for alarm review and repair planning.

CLUEY for combined heat and power
CLUEY for combined heat and powerby Comtac

Temperature probes and contacts feed a wireless unit with fault, water and mains-failure events.

Water network condition monitoring for utilities
Water network condition monitoring for utilitiesby Microtronics

Field loggers send flow, pressure and quality readings to a platform with alarms and histories.

Transformer condition alerts for substation maintenance teams
Transformer condition alerts for substation maintenance teamsby Dynamic Ratings

Electrical sensors feed winding, bushing and tap-changer readings to software for fault review.

More from Algodue

Load electricity metering for facility managers
Load electricity metering for facility managersMulti-circuit meters send readings over RS485 Modbus RTU for demand review and cost…

Questions and answers

Which sensor outputs match the transformer's instrument version?

The transformer version of PQM4000 accepts standard current transformers with 1 A or 5 A outputs. A separate instrument version accepts current clamps.

Can the analyzer examine neutral potential or earth leakage?

Additional voltage and current channels support neutral-potential and earth-leakage current monitoring.

Which file formats carry event records into an analysis workflow?

PQM4000 records data in PQDIF and CSV formats and supports USB transfer as well as network access.

What network protocols connect the instrument with a supervisory system?

The instrument supports Modbus RTU over RS485 and Modbus TCP over Ethernet, alongside its embedded web interface.

How can event timing be aligned with other electrical records?

Integrated GPS provides timing for recorded data, supporting comparison of events between measurement sources.

What will this deployment cost?

Every page carries a cost estimate by IoT Apps for your own sites and assets; set your budget and invite Algodue to confirm a price and lead time.

What does a deployment cost?

For 1 site with 10 monitored assets in United States, IoT Apps estimates $1,400 – $4,700 in the first year and $300 – $1,000 every year after. This is an estimate based on comparable deployments, not a quote from Algodue.

VendorAlgodue
ConnectivityWi-Fi, Ethernet, RS-485
DeploymentEdge/Local
ServicesSoftware Platform, Support & Maintenance
Hardware modelRequired, Proprietary, Not Required
Available inWorldwide

Uses this hardware

Mandatory
Algodue PQM4000
Algodue PQM4000Algodue · PQM4000 · Sensor, Wired

Have a question for Algodue?

IoT Apps Enterprise

Not sure this fits your deployment?

Ask the AI Solution Architect: compare this solution against alternatives, check connectivity for your region and get integration guidance. Included with IoT Apps Enterprise.

Ask the Architect
IoT Apps is an independent platform. Listings do not imply endorsement by or partnership with the vendor. Estimates are indicative and based on comparable deployments, not on vendor quotes.